QUALITY Check

Status Implementation Issue K2 K3

Context​

A collection can end up internally inconsistent without the user doing anything wrong. The first case found — 2026-09-19, while investigating a real collection where "some storage are not matching their device anymore" — is Collection Import leaving a Storage device pointing at a storage row that no longer exists, or at the wrong one.

The response is not a silent automatic repair on open. A collection is the user's data; a program that quietly rewrites links is exactly what created the problem. Instead: a Quality Check the user runs, which reports what it found, and repairs only what the user tells it to.

This page records what can break and how to detect it — see issue #809.

Phases. The feature is delivered in two phases:

  • Phase 1 — diagnosis only. The Quality Check runs the checks and reports what it found. It repairs nothing and writes nothing (QCK-C7). Its rows are [Planned].
  • Phase 2 — repair. The Repair section below, QCK-F5, QCK-F6 and the Memory-mode write-back of QCK-C5. Not in the first cut; those rows stay [Backlog].

Reading the requirement IDs. Each requirement has a permanent ID. IDs are never renumbered or reused; a retired requirement is marked [Removed], not deleted. Status is one of [Implemented] / [Planned] / [Backlog] / [Removed].


Scope at a glance​

In scopePhase 1: a user-triggered, read-only check over the open collection, started from the K3 Settings page; a report of what it found, which can be copied as plain text; the checks listed below. Phase 2 (later): repairs the user chooses to apply
Out of scopeAutomatic repair on open; repair without a report; any write at all in phase 1; checking file contents on disk; the file, filetemp and folder tables; anything that writes outside the collection
Applies toK3 3.0. K2 is in maintenance mode and gets no new UI for this
Depends onSpecStorageIdentity.md for what a correct storage link looks like, and for the rule that a duplicate written storage number is allowed (STI-O3, STI-F6); SpecValidationRules.md for the report window's buttons and the Copy confirmation channel

What is known to break​

1. Storage device pointing at nothing​

A Storage device's device.device_external_id names a storage.storage_id that does not exist. The device shows blank storage details — no brand, no model, no serial.

Cause: Collection Import renumbers the storage row (storage_id becomes source id + MAX(storage_id) + 1 in the target) but copies device_external_id across unchanged. The two no longer agree.

2. Storage device pointing at the wrong disk​

Same cause, worse outcome. The stale device_external_id happens to match a different storage row that already existed in the target. The device then silently shows another drive's brand, model, serial and label — and the number written on its case.

This is the dangerous one, because nothing looks broken. It is no longer detected — see "Detection given up" below.

3. Storage device with no storage row at all​

importStorageForCatalog() runs only for Catalog devices. A Storage device with no catalogs beneath it — or whose catalogs name a storage already present in the target — never gets a storage row created for it at all.

The delete hazard​

Device::deleteDevice() resolves the storage row the same way the display does:

storage->ID = externalID;
storage->deleteStorage();

So deleting a Storage device affected by case 2 deletes a different disk's storage row. Until the Quality Check exists, a collection suspected of this should have its storage links checked before any Storage device is deleted.


Detection​

These are the checks the feature performs. They are written here as SQL so they can be run by hand on a File-mode collection in the meantime.

Check 1 — devices pointing at a missing storage row

SELECT d.device_id, d.device_name, d.device_external_id
FROM device d
LEFT JOIN storage s ON s.storage_id = d.device_external_id
WHERE d.device_type = 'Storage' AND s.storage_id IS NULL;

Check 2 — retired. It compared a Storage device's name with storage.storage_name. Under SpecStorageIdentity.md STI-C13 the device name is the only name and storage_name is removed, so this check is withdrawn together with QCK-F3. The number is kept free so the remaining checks keep their numbers.

Check 3 — storage rows nothing points at

SELECT s.storage_id, s.storage_user_id
FROM storage s
LEFT JOIN device d ON d.device_external_id = s.storage_id
AND d.device_type = 'Storage'
WHERE d.device_id IS NULL
ORDER BY s.storage_id;

No device points at these rows, so they have no name to show: they are listed by internal id and by the number written on the disk.

Check 4 — storage rows sharing the same written number (informational)

SELECT s.storage_user_id, s.storage_id, COALESCE(d.device_name, '')
FROM storage s
LEFT JOIN device d ON d.device_external_id = s.storage_id
AND d.device_type = 'Storage'
WHERE s.storage_user_id IS NOT NULL AND s.storage_user_id <> 0
AND s.storage_user_id IN (SELECT storage_user_id FROM storage
GROUP BY storage_user_id HAVING COUNT(*) > 1)
ORDER BY s.storage_user_id, s.storage_id;

A duplicate written number is allowed: SpecStorageIdentity.md STI-O3 and STI-F6 let two disks carry the same number and only warn on save; zero means "no number" and is exempt. Each row is named by the Storage device that points at it (empty if none). This check therefore reports duplicates for the user's information. It is not a defect, and phase 2 has no repair for it.

Check 5 — retired. It grouped storage rows by storage.storage_name. The column is removed (STI-C13), so this check is withdrawn together with QCK-F9. The number is kept free.

Check 6 — Catalog devices pointing at a missing catalog row

SELECT d.device_id, d.device_name, d.device_external_id
FROM device d
LEFT JOIN catalog c ON c.catalog_id = d.device_external_id
WHERE d.device_type = 'Catalog' AND c.catalog_id IS NULL;

Check 7 — catalog rows no Catalog device points at

SELECT c.catalog_id, c.catalog_file_path
FROM catalog c
LEFT JOIN device d ON d.device_external_id = c.catalog_id
AND d.device_type = 'Catalog'
WHERE d.device_id IS NULL;

No device points at these rows, so they have no name to show (catalog_name is removed, SpecStorageIdentity.md STI-C17): they are listed by id and by their catalog file path.

Check 8 — devices whose parent does not exist

SELECT d.device_id, d.device_name, d.device_parent_id
FROM device d
LEFT JOIN device p ON p.device_id = d.device_parent_id
WHERE d.device_parent_id IS NOT NULL AND d.device_parent_id <> 0
AND p.device_id IS NULL;

A device_parent_id of 0 or NULL marks a root device and is not reported.

Checks 1 and 3 are usually two views of the same break: a device orphaned by the renumbering, and the row it should have been pointing at. Checks 6 and 7 are the same pair for catalogs.

Detection given up. With check 2 retired, no check detects a Storage device pointing at the wrong disk (case 2 above). Such damage comes only from imports done before the import fix of SpecStorageIdentity.md (STI-F1 to STI-F3); it stays in those collections undetected. QCK-O3, which asked for it, is retired.

Tables each check reads. Checks 1, 3 and 4: device, storage. Checks 6 and 7: device, catalog. Check 8: device. No check reads file, filetemp or folder. storage_name, catalog_storage and catalog_name no longer exist (STI-C13, STI-C17).

Memory mode. All three tables are loaded when the collection is opened (Collection::load()): device from device.csv, storage from storage.csv, and catalog from the header lines of every .idx file in the collection folder. So every check applies as soon as the collection is open, and none needs the per-catalog file/folder pre-load. One caution for checks 6 and 7: in Memory mode catalog_id comes from the .idx header, and a catalog written before 2.8 carries no id there and loads as 0 — such a catalog will show up in check 7, and a Catalog device pointing at it in check 6. That is a true finding about the loaded data, not a false positive of the check.


Repair​

Phase 2 — not in the first cut. Phase 1 reports only; nothing in this section is built until phase 2.

No repair case is currently defined. The only repair case previously described — re-pointing a device found by check 1 at a storage row whose storage_name equals the device name — was removed by the user: it read storage_name, which SpecStorageIdentity.md STI-C13 forbids, and names are not a reliable way to manage the device hierarchy (STI-C14). A phase 2 repair case needs its own requirement.

Whatever repair is later defined: nothing is written until the user accepts. A repair that cannot be made unambiguously is reported, never guessed.


Operational requirements — why / for whom​

IDRequirementStatus
QCK-O1A user who suspects something is wrong with a collection can ask Katalog to check it, and gets a plain list of what it found.[Planned]
QCK-O2A user decides which problems get fixed. Katalog does not repair a collection on its own initiative.[Planned]
QCK-O3A user is warned about damage that is invisible in normal use — above all a storage device showing another disk's details. Retired: it was only covered by check 2 (QCK-F3), itself retired under SpecStorageIdentity.md STI-C13.[Removed]

Functional requirements — what the system does​

IDRequirementStatus
QCK-F1The Quality Check is started by the user and runs over the collection that is open.[Planned]
QCK-F2It reports every Storage device whose device_external_id matches no storage.storage_id (check 1).[Planned]
QCK-F3It reports every Storage device whose device_external_id matches a storage row whose storage_name differs from the device's device_name (check 2). Retired: storage_name is no longer read (SpecStorageIdentity.md STI-C13).[Removed]
QCK-F4It reports every storage row that no Storage device points at (check 3).[Planned]
QCK-F5For each problem it can repair unambiguously, it offers the repair and applies it only when the user accepts. Phase 2 — not in the first cut.[Backlog]
QCK-F6A problem with no unambiguous repair is reported with what was found, and nothing is written. Phase 2 — not in the first cut.[Backlog]
QCK-F7The report says plainly when nothing was found, so a clean collection gives a clear answer rather than an empty screen.[Planned]
QCK-F8It reports every group of two or more storage rows sharing the same non-zero storage_user_id (check 4). This is informational: a duplicate written number is allowed by STI-O3 / STI-F6, so the report presents it as something to know, not as damage, and zero is never reported.[Planned]
QCK-F9It reports every group of two or more storage rows sharing the same storage_name (check 5). Retired: storage names need no uniqueness and are no longer read (SpecStorageIdentity.md STI-C13).[Removed]
QCK-F10It reports every Catalog device (device_type = 'Catalog') whose device_external_id matches no catalog.catalog_id (check 6).[Planned]
QCK-F11It reports every catalog row that no Catalog device points at (check 7).[Planned]
QCK-F12It reports every device whose device_parent_id is neither 0/NULL (root) nor an existing device.device_id (check 8).[Planned]
QCK-F13In K3, the Quality Check is started by a button on the Settings page, Collection tab (SpecSettingsPage.md SET-F3), in the "Collection & Database" section, on the "Database Version" row, placed next to the version value — the same value-plus-button pattern as the Collection row's Edit button. K2 gets no entry point.[Planned]
QCK-F14The report is shown in a window with one section per check. Each section shows the number of rows found and lists them; each row identifies the item by its id, and also by its name when a device holds one. Checks 3 and 7 list records that no device points at, so they show ids only: check 3 shows storage_id and storage_user_id, check 7 shows catalog_id and catalog_file_path.[Planned]
QCK-F15Each check that finds nothing says so explicitly in its own section, in addition to the overall statement of QCK-F7.[Planned]
QCK-F16The report window has a Copy action that puts the whole report on the clipboard as plain text, and confirms it with a transient passive notification.[Planned]

Constructional requirements — how it is built / limits / MUST-NOTs​

IDRequirementStatus
QCK-C1The checks and the repairs live in core/. The UI starts the check, shows the report and passes back what the user accepted.[Planned]
QCK-C2The Quality Check MUST NOT run automatically — not on open, not on import, not on a timer. It runs when the user asks for it.[Planned]
QCK-C3It MUST NOT write anything the user has not accepted, and MUST NOT delete a device or a storage row as part of a repair.[Planned]
QCK-C4It reads and writes the open collection only. It MUST NOT touch files outside the collection folder.[Planned]
QCK-C5It works in Memory, File and Hosted modes. In Memory mode the repaired tables are written back to their .csv files, or the repair is lost on close. Phase 1 builds the first sentence; the Memory-mode write-back is phase 2.[Planned]
QCK-C6New checks are added as new QCK-F rows. The feature is not a general "fix the database" command and MUST NOT grow into one without its own requirements.[Planned]
QCK-C7Phase 1 is strictly read-only. It MUST NOT write to the database or to any collection file — no INSERT, UPDATE, DELETE or schema change, and no .csv, .idx or .ini write.[Planned]

User-visible text​

None approved yet. Removing the report sections of the retired checks 2 and 5 removes their user-visible labels; each removal needs its own per-string approval at implementation time, and none is decided here.

Every string this feature needs — the report headings, the repair offer, the "nothing found" message — requires its own approval before it is written. No wording is proposed here.


Manual test charter​

  • QCK-F2 — Import a collection into a non-empty one so a Storage device is orphaned. Run the check: the device is listed.
  • QCK-F5 (phase 2) — No repair case is defined; nothing to test until one is.
  • QCK-F3 / QCK-F9 (removed) — Give a Storage device a name different from its storage_name, and give two storage rows the same storage_name. Run the check: the report has no section for either, and nothing is reported for them.
  • QCK-F4 — Leave a storage row nothing points at. Run the check: it is listed.
  • QCK-F6 (phase 2) — No repair case is defined; nothing to test until one is.
  • QCK-F7 — Run the check on a healthy collection: it says so.
  • QCK-C2 — Open a collection, import into it, wait: the check never runs by itself.
  • QCK-C5 — (Phase 2, once a repair case is defined) apply it in Memory mode, close and reopen the collection: the repair is still there. Phase 1: run the check on the same collection in Memory, File and Hosted mode: it completes and reports in each.
  • QCK-F8 — Give two storages the same non-zero Storage ID and two others Storage ID 0. Run the check: the pair is listed as informational, the zeros are not listed.
  • QCK-F10 — Set a Catalog device's device_external_id to an id no catalog has. Run the check: the device is listed.
  • QCK-F11 — Leave a catalog row no Catalog device points at. Run the check: the catalog is listed.
  • QCK-F12 — Set a device's device_parent_id to an id no device has. Run the check: the device is listed; root devices (parent 0) are not.
  • QCK-F13 — In K3, open Settings: the button sits on the "Database Version" row next to the version value, laid out like the Collection row's Edit button, and starts the check. In K2 nothing has changed.
  • QCK-F14 — Run the check on a damaged collection: the window shows one section per check, each with its count and its rows identified by id, plus the device name where a device holds one (checks 3 and 7: ids only).
  • QCK-F15 — Run the check on a collection with only one kind of damage: every other section says it found nothing.
  • QCK-F16 — Use Copy, paste into a text editor: the whole report arrives as plain text, and a passive notification confirmed the copy.
  • QCK-C7 — On a File-mode collection, note the database file's modification time and checksum; on a Memory-mode collection, those of every .csv, .idx and .ini in the collection folder. Run the check. Nothing has changed.

  • SpecStorageIdentity.md — what a correct storage link is, the import fix that stops new damage, and STI-C13 (the device name is the only name read)
  • Issue #809